MSS Client / Domain Client Version 2.2 PTF 11
September 13, 2004

PTF 11 is a cumulative PTF, it includes all fixes from PTF 1 through 10.

------------------------------------------------------------------------------------------------

Below is a list of fixes included in MSS Client/Domain Client:

 

NA06467 > 64 SNMP communities not supported causing reset.

NA06480 ELS filtering not working for Net 0 and message without interface number

Other fixes include:

SNMP fixes made in SNMP CERT SECURITY tests of other products included in MSS Client code.

 

**************************************************************************

The fixes below were included in previous PTFs:

PTF 10

-------

NA06451 Fix CERT SNMP SECURITY TEST failure.

IR46812 BUFFER LEAK IN THE MSS CLIENT'S LNM BUFFERS.

IR45950 MSS exception event may cause crash when routing frames out TR LEC

NA06254 OSPF LIST AREA command provides incorrect output.

NA06418 TCP connection not being terminated properly resulting in leak.

 

PTF 9

------

IR43976    ATM LEC may not efficiently switch to proper VCC.
 

PTF 8
------

IR43367    No FASTR Ports are visible in Netview


PTF 7
------

Note:  PTF 7 was released for MSS Serveronly (PTF 7 for MSS Client / Domain Client was not released).
 

PTF 6
------

These new functions will become part of the base function for all subsequent PTFs. Please refer to the MSSConfiguring Protocols Vol. 1 for details on how these functions can be configured.

*** Note: MSS Client Config Tool Version 2.2 PTF 3 is required to configure the new functions above.

            -RFC 1483 Bridging

            -Port Based VLANs

            -Distributed IP Gateway

            -Redundant Default Gateway

            -Virtual Router Redundancy Protocol (VRRP)

            For more information on VRRP:

 ftp://ftp.networking.ibm.com/ess/public/docs/03C42B34D9F6AD4D8525678400670222/AMN9MS24.HTM#HDRVRRP
 
 

PTF 5
------

IR40945 Internal timers may not start properly on platforms withoutATM adapter.

IR40675 Persistent VCCS are not able to move to backup then back toprimary correctly.

            MSS Client may crash under extreme broadcast traffic situation.

            TEST SEGMENT command fails when sent to the MSS Client

            MSS Client fails when fiber cable repeatedly unplugged/plugged.

PTF 4
------

IR40383 MSS NETBIOS BCM may not account for ill behaved PC.

IR40141 REDUNDANT IP GATEWAY Address is not shown in MIB browse.

IR40733 ATM interface will not allow than 4096 connections.

IR40779 MSS SAAL becomes unstable with large number of vccs.

            MSS Client may not behave properly when UNI version is set to 'AUTO'

            LNM agent does not send accurate hop count information

            ATM Alarm BugHlt caused by duplicate parameters in a config.